Benzene 5/a, 5 - 40 PPM, (6718801)
Benzene 5/a, 5 - 40 PPM, Part # 6718801, 10 Tests
Application Range
Standard Measuring Range: 5 to 40 ppm
Number of Strokes n: 15 to 2
Time for Measurement: max. 3 min
Standard Deviation: ± 30 %
Color Change: white red brown
Ambient Operating Conditions
Temperature: 0 to 40 °C
Absolute Humidity: max. 50 mg H2O / L
Reaction Principle
2 C6H6 + HCHO C6H5-CH2-C6H5 + H2O
C6H5-CH2-C6H5 + H2SO4 p-quinoid compound
Cross Sensitivity
Other aromatics (toluene, xylene) are retained in the pre-layer causing a reddish brown discoloration. If the toluene or xylene concentrations are too high the entire pre-layer up to the indicating layer is discolored making a benzene measurement impossible. Petroleum hydrocarbons, alcohols and esters do not affect the indication