Now Selling Draeger Gas Detection & Respiratory Products
Now Selling Draeger Gas Detection & Respiratory Products
Cart 0
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607
Solinst

Solinst Model 3001 Levelogger 5 Junior M10 Part# 114607

Regular price $426.40 Sale price $544.00 Unit price per
Shipping calculated at checkout.

Solinst Model 3001 Levelogger 5  Junior M10 Part#114607

The Levelogger Junior Edge provides an inexpensive alternative for measuring groundwater and surface water levels and temperature. The Levelogger Junior Edge combines a pressure sensor, temperature detector, a datalogger, and 5-year battery
 (based on a 1-minute sampling rate) in one compact 7/8" x  5.6" (22 mm x 142 mm) stainless steel housing.

The Levelogger Junior Edge records absolute pressure using the same durable Hastelloy® pressure sensor as the Levelogger Edge. The Hastelloy sensor has excellent performance in harsh environments with better temperature compensation and thermal response time, and can withstand 2 times overpressure without permanent damage. 

The Levelogger Junior Edge features FRAM memory, with a capacity of 40,000 sets of temperature and water level data points. Readings are linear at a user-defined interval between 0.5 second to 99 hours. Accuracy is 0.1% FS, with lifetime factory calibration.

If greater accuracy, more sampling options, or wider depth ranges are required, the Solinst Levelogger Edge has the functionality to suit your application (see Model 3001 Edge data sheet). For conductivity datalogging, Solinst also offers the LTC Levelogger Edge (see Model 3001 LTC Levelogger Edge data sheet). 

Features

• Low cost

•  Accuracy of 0.1% FS

•  Memory for 40,000 data points

•  Robust Hastelloy pressure sensor

• Basic and advanced data compensation options


Operation

Programming the Levelogger Junior Edge is the same as with the Levelogger Edge. An Optical Reader or PC Interface Cable connects the Levelogger to a laptop or desktop PC. The intuitive Levelogger Software automatically detects the type of Levelogger that is connected. Programming, downloading, data management and export are intuitive tasks. The Real Time View option allows immediate viewing of live water level and temperature readings, independent of the scheduled programming intervals.

The Levelogger Junior Edge outputs temperature and temperature compensated water level readings. Using the Data Wizard in the Levelogger Software, you can barometrically compensation multiple Levelogger Junior Edge files simultaneously, with just one Barologger Edge file.

The Levelogger Junior Edge is compatible with Levelogger Series accessories, including the Solinst Levelogger App and Interface, the DataGrabber data transfer device, SDI-12 Interface Cable, and Solinst Telemetry Systems.

These compact dataloggers are straightforward to deploy.  Installation can be with direct read cables, by stainless steel wireline or Kevlar® cord suspension, with the option of using Solinst 2" Locking Well Caps.

Applications

•  Monitoring water levels in wells and surface water

• Pump and slug tests

•  Reservoir and stormwater runoff management

•  Watershed and drainage basin monitoring

•  Stream gauging, lake and wetland monitoring

•  Tank level measurement

Level Sensor: Piezoresistive Silicon with Hastelloy

Sensor Ranges: 5,10 m

Accuracy: ± 0.1% FS

Resolution: 0.02% FS to 0.01% FS

Units of Measure: cm, m, ft, psi, kPa, bar, (ºC, ºF)

Normalization: Automatic Temp Compensation Temp Compensation

Range: 0ºC to 40ºC

Temperature Sensor: Platinum Resistance Temperature Detector (RTD)

Accuracy: ± 0.1ºC Resolution: 0.1ºC

Battery Life: 5 Years (based on 1 reading/minute)

Operating Temperature: - 20ºC to 80ºC

Clock Accuracy: ± 1 minute/year (- 20ºC to 80ºC)

Memory: FRAM Maximum Readings: 40,000 sets of readings

Communication: Optical Infrared to USB, RS232, or SDI-12

Size: 7/8" x  5.6" (22 mm x 142 mm)

Weight: 4.2 oz. (119 grams)

Wetted Materials: 316 Stainless Steel, Delrin®, Viton®, Hastelloy

Sampling Mode: Linear, Real Time View, Future Start

Measurement Rates: 0.5 sec to 99 hours

Barometric Compensation: Data Wizard and Barologger Edge

® Hastelloy is a registered trademark of Haynes International Inc. ® Delrin, Viton and Kevlar are registered trademarks of DuPont Corp. 

LT Models          Full Scale (FS)           Accuracy                  Resolution

M5                        5 m (16.4 ft)          ± 0.6 cm, 0.020 ft.           0.02% FS

M10                     10 m (32.8 ft)         ± 1.0 cm, 0.032 ft.           0.01% FS


Flexible Communication

Levelogger PC Software is streamlined, making it easy to program dataloggers, and to view and compensate data, in the office or in the field. The software has useful programming options, including compressed and repeat sampling, and future start/stop. Data compensation has been simplified, and allows multiple data files to be barometrically compensated at once.

The extremely intuitive Solinst Levelogger App, and Levelogger App Interface on your in-field Leveloggers, creates a Bluetooth® connection between your Leveloggers and smart device. Also an option, the DataGrabber is a field-ready, USB data transfer unit designed specifically for the Levelogger Series.

Remote monitoring options include the LevelSender, a simple and compact device that fits right in a 2" well, STS Telemetry Systems, and RRL Remote Radio Link. In addition, Levelogger Series dataloggers are SDI-12 compatible.

Levelogger Setup

Programming Leveloggers is extremely intuitive. Simply connect to a PC using an Optical Reader or PC Interface Cable. All in one screen fill in your project information and sampling regime. Templates of settings can be saved for easy re-use.

The Levelogger time may be synchronized to the computer clock. There are options for immediate start or future start and stop times. The percentage battery life remaining and the amount of free memory are indicated on the settings screen.

Leveloggers can also be programmed with a sampling regime  and start/stop times using the Solinst Levelogger App on your smart device. 

Data Download, Viewing and Export

Data is downloaded to a PC with the click of a screen icon. There are multiple options for downloading data, including ‘Append Data’ and ‘All Data’. The software also allows immediate viewing of the data in graph or table format using the ‘Real Time View’ tab.

The level data is automatically compensated for temperature, and the temperature data is also downloaded. Barometric compensation of Levelogger data is performed using the Data Wizard, which can also be used to input manual data adjustments, elevation, offsets, density, and adjust for Barometric efficiency.

The software allows easy export of the data into a spreadsheet or database for further processing.

The Solinst Levelogger App also allows you to view and save
 real-time, or logged data right on your smart device.

Helpful Utilities

The ‘Self-Test Diagnostic Utility’ can be used in case of an unexpected problem. It checks the functioning of the program, calibration, backup and logging memories, the pressure transducer, temperature sensor and battery voltage, as well as enabling a complete Memory Dump, if required. 

A firmware upgrade will be available from time to time, to allow upgrading of the Levelogger Edge, as new features are added. 

Solinst Levelogger App & Levelogger App Interface

The Levelogger App Interface uses Bluetooth® technology to connect your Levelogger to your smart device. With the Solinst Levelogger App, you can download data, view real-time data, and program your Leveloggers. Data can be e-mailed from your smart device directly to your office (see Model 3001 Levelogger App & Interface)

DataGrabber™

The DataGrabber is a field-ready data transfer device that allows you to copy data from a Levelogger, onto a USB flash drive key.

The DataGrabber is compact and very easy to transport. It connects to the top end of a Levelogger’s Direct Read Cable, or an Adaptor is available to allow direct connection to a Levelogger.

One push-button is used to download all of the data in a Levelogger’s memory to a USB device plugged into the DataGrabber. A convenient LED light indicates the operation of the DataGrabber. The data in the Levelogger memory is not erased, and logging is not interrupted if the Levelogger is still running. The DataGrabber uses its own replaceable 9V battery.

Standard Cable Deployment

Leveloggers may be suspended on a stainless steel wireline or Kevlar® cord. This is a very inexpensive method of deployment, and if in a well, allows the Levelogger to be easily locked out of sight and inaccessible. Solinst offers stainless steel wireline assemblies and Kevlar cord assemblies in a variety of lengths. 

Solinst 3001 Well Cap Assembly

The 2" Locking Well Caps are designed for both standard and Direct Read Cable deployment options.

The well cap has a convenient eyelet for suspending Leveloggers using wireline or Kevlar cord. The Well Cap insert has two openings to accommodate Direct Read Cables for both a Levelogger and Barologger. Adaptors are available to fit 4" wells.

The cap is vented to equalize atmospheric pressure in the well. It slips over the casing, and the cap can be secured using a lock with a 3/8" (9.5 mm) shackle diameter.

Direct Read Cables

When it is desired to get realtime data and communicate with Leveloggers without removal from the water, they can be deployed using Direct Read Cables. This allows viewing of the data, downloading and/or programming in the field using a portable computer, DataGrabber, or the Solinst Levelogger App and Interface.

Leveloggers can also be connected to an SDI-12 datalogger using the Solinst SDI-12 Interface Cable attached to a Direct Read Cable. 


Cable Specifications Direct Read Cables are available for attachment to any Levelogger in lengths up to 1500 ft.

The 1/8" dia. (3.175 mm) coaxial cable has an outer polyurethane jacket for strength and durability. The stranded stainless steel conductor gives non-stretch accuracy. 

Accurate Barometric Compensation

The Levelogger Edge measures absolute pressure (water pressure + atmospheric pressure) expressed in feet, meters, centimeters, psi, kPa, or bar.

The most accurate method of obtaining changes in water level is to compensate for atmospheric pressure fluctuations using a Barologger Edge, avoiding time lag in the compensation.

The Barologger is set above high water level in one location on site. One Barologger can be used to compensate all Leveloggers in a 20 mile (30 km) radius and/or with every 1000 ft. (300 m) change in elevation.

The Levelogger Software Data Compensation Wizard automatically produces compensated data files using the synchronized data files from the Barologger and Leveloggers on site.

The Barologger Edge uses pressure algorithms based on air rather than water pressure, giving superior accuracy. 

The recorded barometric information can also be very useful to help determine barometric lag and/or barometric efficiency of the monitored aquifer.

The Barologger Edge records atmospheric pressure in  psi, kPa, or mbar. When compensating submerged Levelogger Edge, Gold or Junior data, Levelogger Software Version 4 can recognize the type of Levelogger and compensate using the same units found in the submerged data file (Levelogger Gold and Junior measure in feet, meters, or centimeters). This makes the Barologger Edge backwards compatible.